{"id":158,"date":"2026-04-07T13:10:54","date_gmt":"2026-04-07T10:10:54","guid":{"rendered":"https:\/\/rezonanskalibrasyon.com\/en\/?post_type=hizmetler&#038;p=158"},"modified":"2026-04-08T13:43:44","modified_gmt":"2026-04-08T10:43:44","slug":"rf-microwave-calibration","status":"publish","type":"hizmetler","link":"https:\/\/rezonanskalibrasyon.com\/en\/hizmetler\/rf-microwave-calibration\/","title":{"rendered":"RF Microwave Calibration"},"content":{"rendered":"\n<p><strong>RF Microwave Calibration , Rezonans Calibration Laboratory provides RF calibration services. Accredited RF Power and Frequency measurements can be performed in the 0-18 GHz range. Services are also available in the 18 GHz \u2013 26.5 GHz range, but outside of this scope.<\/strong><\/p>\n\n\n\n<p><strong>Our company offers boutique services using top-of-the-line equipment that meets international standards.<\/strong><\/p>\n\n\n\n<p><strong>The device groups for which we perform RF Microwave Calibration are listed below.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Rf signal generator<\/strong><\/td><td><strong>RF Power meter<\/strong><\/td><\/tr><tr><td><strong>Frequency Counter <\/strong><\/td><td><strong>Function Generator <\/strong><\/td><\/tr><tr><td><strong>Power Splitter \u2013 Divider<\/strong><\/td><td><strong>Rf Antenna test<\/strong><\/td><\/tr><tr><td><strong>Spectrum Analyzer <\/strong><\/td><td><strong>Network Analyzer<\/strong><\/td><\/tr><tr><td><strong>Rf Power Amplifier<\/strong> <\/td><td><strong>Rf site master <\/strong><\/td><\/tr><tr><td><strong>Attenuator <\/strong><\/td><td><strong>Communication Test Set<\/strong><\/td><\/tr><tr><td><strong>Signal Generator<\/strong><\/td><td><strong>Rf Level Generator <\/strong><\/td><\/tr><tr><td><strong>Rf Level Meter <\/strong><\/td><td><strong>Variable Attenuator (&lt; 20 GHz)<\/strong><\/td><\/tr><tr><td><strong>RF Power meter and Sensor <\/strong> <strong>(&lt; 26,5 GHz) <\/strong><\/td><td><strong>Fixed Attenuator<\/strong> <strong>(&lt; 20 GHz) <\/strong><\/td><\/tr><tr><td><strong>Rf Oscillator<\/strong><\/td><td><strong>Rf power sensor (&lt; 20 GHz)<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>RF power, time, frequency, amplitude, Vswr, and voltage calibration parameters are measured. For RF power measurements, we can perform calibration measurements for power levels between -70 and +20 dBm (+43 dBm 20w) within the 0-18 GHz range and outside the 18-26.5 GHz range.<\/strong><\/p>\n\n\n\n<p><strong>For frequency calibration, we use a Meinberg Network time server to maximize measurement accuracy. We can achieve measurements with an accuracy of <em>10<\/em>\u207b<\/strong><sup>12<\/sup><strong>.<\/strong><\/p>\n\n\n\n<p><strong>For RF power measurements, our laboratory uses world-renowned attenuators to measure RF power of 100W and above. As a company, we offer high-end RF and microwave calibration services, difficult to find in Turkey, for your critical projects in the defense and aerospace industries, with our US-based (NAC-008-CL) ISO\/IEC 17025 accreditation.<\/strong><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Why Work With Us?<\/h4>\n\n\n\n<p><strong>Pushing the Boundaries of Microwaves: Unlike standard laboratories, we provide services with the lowest uncertainty rates across a wide spectrum up to the 26.5 GHz frequency band.<\/strong><br><strong>High Power Expertise: With our 350W RF Attenuator and Amplifier infrastructure, we reliably and accurately measure the high output power of your radar and jammer systems.<\/strong><br><strong>Precise Timing: We meet your time and frequency synchronization (NTP\/PTP) needs with Meinberg Time Network according to international standards.<\/strong><br><strong>International Audit Compliance: Thanks to our ILAC-MRA signature, we produce certificates that will be directly accepted in your export projects (NATO, FAA, EASA compliant) without the need for an additional approval process.<\/strong> <strong>RF Microwave Calibration<\/strong><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>RF Microwave Calibration<\/strong><\/h4>\n\n\n\n<p><strong>Our Key CMC Capabilities:<\/strong><\/p>\n\n\n\n<p><strong>Frequency: 18 GHz and above, high-stability measurement.<\/strong><\/p>\n\n\n\n<p><strong>RF Power: Pulse Modulation analysis power measurement.<\/strong><\/p>\n\n\n\n<p><strong>Connection Quality: Use of \u201cPhase Stable\u201d cables such as Huber+Suhner and Pasternack, and Huber-Suhner and Amphenol connector adapter sets in all measurements.<\/strong><\/p>\n\n\n\n<p><strong>As a company, we provide not only calibration certificates but also engineering data and design verification certificates.<\/strong><\/p>\n\n\n\n<p><strong>We perform on-site measurements to speed up your processes.<\/strong><\/p>\n\n\n\n<p><strong>Technical Verification and Performance Testing.<\/strong><\/p>\n\n\n\n<p><strong>We do not keep the devices of our contracted companies waiting for a week; we provide results the same day.<\/strong><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">To avoid the cost and time loss of shipping your devices abroad, please review our attached Scope Table (CMC).<\/h4>\n\n\n\n<p>RF Microwave Calibration Process (General Steps):<\/p>\n\n\n\n<p>Preparation: Preparing the device to be calibrated and the necessary reference standards. Ensuring the device is clean and in working order.<br>Connections: Connecting the device and reference standards correctly using appropriate cables and adapters.<br>Measurements: Reading the values \u200b\u200bof the device at specific points (frequency, power level, etc.) using the reference standards.<br>Comparison: Comparing the measured values \u200b\u200bwith the reference values \u200b\u200band identifying deviations.<br>Documentation: Preparing a calibration certificate that includes the calibration results, the reference standards used, the environmental conditions, and the uncertainty analysis.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"411\" src=\"https:\/\/rezonanskalibrasyon.com\/en\/wp-content\/uploads\/sites\/2\/2026\/03\/rf-mikrodalga-kalibrasyonu-1-1024x411.webp\" alt=\"\" class=\"wp-image-165\" style=\"aspect-ratio:2.6597708442264283;width:519px;height:auto\" srcset=\"https:\/\/rezonanskalibrasyon.com\/en\/wp-content\/uploads\/sites\/2\/2026\/03\/rf-mikrodalga-kalibrasyonu-1-1024x411.webp 1024w, https:\/\/rezonanskalibrasyon.com\/en\/wp-content\/uploads\/sites\/2\/2026\/03\/rf-mikrodalga-kalibrasyonu-1-300x121.webp 300w, https:\/\/rezonanskalibrasyon.com\/en\/wp-content\/uploads\/sites\/2\/2026\/03\/rf-mikrodalga-kalibrasyonu-1-768x309.webp 768w, https:\/\/rezonanskalibrasyon.com\/en\/wp-content\/uploads\/sites\/2\/2026\/03\/rf-mikrodalga-kalibrasyonu-1.webp 1277w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/rezonanskalibrasyon.com\/en\/hizmetler\/rf-microwave-calibration\/\">RF Microwave Calibration<\/a><\/h3>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>RF Microwave Calibration , Rezonans Calibration Laboratory provides RF calibration services. Accredited RF Power and Frequency measurements can be performed in the 0-18 GHz range. Services are also available in the 18 GHz \u2013 26.5 GHz range, but outside of this scope.<\/p>\n","protected":false},"featured_media":159,"template":"","class_list":["post-158","hizmetler","type-hizmetler","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/rezonanskalibrasyon.com\/en\/wp-json\/wp\/v2\/hizmetler\/158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rezonanskalibrasyon.com\/en\/wp-json\/wp\/v2\/hizmetler"}],"about":[{"href":"https:\/\/rezonanskalibrasyon.com\/en\/wp-json\/wp\/v2\/types\/hizmetler"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rezonanskalibrasyon.com\/en\/wp-json\/wp\/v2\/media\/159"}],"wp:attachment":[{"href":"https:\/\/rezonanskalibrasyon.com\/en\/wp-json\/wp\/v2\/media?parent=158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}